blob: 4e0d0c6c52bc5ce93c5d4b0b2a0965239a88ad3e [file] [log] [blame]
Manual Installation
===================
This document describes how to clone the Contiv repository and then use
`kubeadm <https://kubernetes.io/docs/setup/independent/create-cluster-kubeadm/>`__
to manually install Kubernetes with Contiv-VPP networking on one or more
bare metal or VM hosts.
Clone the Contiv Repository
---------------------------
To clone the Contiv repository enter the following command:
::
git clone https://github.com/contiv/vpp/<repository-name>
**Note:** Replace ** with the name you want assigned to your cloned
contiv repository.
The cloned repository has important folders that contain content that
are referenced in this Contiv documentation; those folders are noted
below:
::
vpp-contiv2$ ls
build build-root doxygen gmod LICENSE Makefile RELEASE.md src
build-data docs extras INFO.yaml MAINTAINERS README.md sphinx_venv test
Preparing Your Hosts
--------------------
Host-specific Configurations
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- **VmWare VMs**: the vmxnet3 driver is required on each interface that
will be used by VPP. Please see
`here <https://github.com/contiv/vpp/tree/master/docs/VMWARE_FUSION_HOST.md>`__
for instructions how to install the vmxnet3 driver on VmWare Fusion.
Setting up Network Adapter(s)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Setting up DPDK
^^^^^^^^^^^^^^^
DPDK setup must be completed **on each node** as follows:
- Load the PCI UIO driver:
::
$ sudo modprobe uio_pci_generic
- Verify that the PCI UIO driver has loaded successfully:
::
$ lsmod | grep uio
uio_pci_generic 16384 0
uio 20480 1 uio_pci_generic
Please note that this driver needs to be loaded upon each server
bootup, so you may want to add ``uio_pci_generic`` into the
``/etc/modules`` file, or a file in the ``/etc/modules-load.d/``
directory. For example, the ``/etc/modules`` file could look as
follows:
::
# /etc/modules: kernel modules to load at boot time.
#
# This file contains the names of kernel modules that should be loaded
# at boot time, one per line. Lines beginning with "#" are ignored.
uio_pci_generic
.. rubric:: Determining Network Adapter PCI Addresses
:name: determining-network-adapter-pci-addresses
You need the PCI address of the network interface that VPP will use
for the multi-node pod interconnect. On Debian-based distributions,
you can use ``lshw``\ (*):
::
$ sudo lshw -class network -businfo
Bus info Device Class Description
====================================================
pci@0000:00:03.0 ens3 network Virtio network device
pci@0000:00:04.0 ens4 network Virtio network device
**Note:** On CentOS/RedHat/Fedora distributions, ``lshw`` may not be
available by default, install it by issuing the following command:
``yum -y install lshw``
Configuring vswitch to Use Network Adapters
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
Finally, you need to set up the vswitch to use the network adapters:
- `Setup on a node with a single
NIC <https://github.com/contiv/vpp/tree/master/docs/SINGLE_NIC_SETUP.md>`__
- `Setup a node with multiple
NICs <https://github.com/contiv/vpp/tree/master/docs/MULTI_NIC_SETUP.md>`__
Using a Node Setup Script
~~~~~~~~~~~~~~~~~~~~~~~~~
You can perform the above steps using the `node setup
script <https://github.com/contiv/vpp/tree/master/k8s/README.md#setup-node-sh>`__.
Installing Kubernetes with Contiv-VPP CNI plugin
------------------------------------------------
After the nodes you will be using in your K8s cluster are prepared, you
can install the cluster using
`kubeadm <https://kubernetes.io/docs/setup/independent/create-cluster-kubeadm/>`__.
(1/4) Installing Kubeadm on Your Hosts
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
For first-time installation, see `Installing
kubeadm <https://kubernetes.io/docs/setup/independent/install-kubeadm/>`__.
To update an existing installation, you should do a
``apt-get update && apt-get upgrade`` or ``yum update`` to get the
latest version of kubeadm.
On each host with multiple NICs where the NIC that will be used for
Kubernetes management traffic is not the one pointed to by the default
route out of the host, a `custom management
network <https://github.com/contiv/vpp/tree/master/docs/CUSTOM_MGMT_NETWORK.md>`__
for Kubernetes must be configured.
Using Kubernetes 1.10 and Above
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
In K8s 1.10, support for huge pages in a pod has been introduced. For
now, this feature must be either disabled or memory limit must be
defined for vswitch container.
To disable huge pages, perform the following steps as root: \* Using
your favorite editor, disable huge pages in the kubelet configuration
file (``/etc/systemd/system/kubelet.service.d/10-kubeadm.conf`` or
``/etc/default/kubelet`` for version 1.11+):
::
Environment="KUBELET_EXTRA_ARGS=--feature-gates HugePages=false"
- Restart the kubelet daemon:
::
systemctl daemon-reload
systemctl restart kubelet
To define memory limit, append the following snippet to vswitch
container in deployment yaml file:
::
resources:
limits:
hugepages-2Mi: 1024Mi
memory: 1024Mi
or set ``contiv.vswitch.defineMemoryLimits`` to ``true`` in `helm
values <https://github.com/contiv/vpp/blob/master/k8s/contiv-vpp/README.md>`__.
(2/4) Initializing Your Master
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Before initializing the master, you may want to
`remove <#tearing-down-kubernetes>`__ any previously installed K8s
components. Then, proceed with master initialization as described in the
`kubeadm
manual <https://kubernetes.io/docs/setup/independent/create-cluster-kubeadm/#initializing-your-master>`__.
Execute the following command as root:
::
kubeadm init --token-ttl 0 --pod-network-cidr=10.1.0.0/16
**Note:** ``kubeadm init`` will autodetect the network interface to
advertise the master on as the interface with the default gateway. If
you want to use a different interface (i.e. a custom management network
setup), specify the ``--apiserver-advertise-address=<ip-address>``
argument to kubeadm init. For example:
::
kubeadm init --token-ttl 0 --pod-network-cidr=10.1.0.0/16 --apiserver-advertise-address=192.168.56.106
**Note:** The CIDR specified with the flag ``--pod-network-cidr`` is
used by kube-proxy, and it **must include** the ``PodSubnetCIDR`` from
the ``IPAMConfig`` section in the Contiv-vpp config map in Contiv-vpp’s
deployment file
`contiv-vpp.yaml <https://github.com/contiv/vpp/blob/master/k8s/contiv-vpp/values.yaml>`__.
Pods in the host network namespace are a special case; they share their
respective interfaces and IP addresses with the host. For proxying to
work properly it is therefore required for services with backends
running on the host to also **include the node management IP** within
the ``--pod-network-cidr`` subnet. For example, with the default
``PodSubnetCIDR=10.1.0.0/16`` and ``PodIfIPCIDR=10.2.1.0/24``, the
subnet ``10.3.0.0/16`` could be allocated for the management network and
``--pod-network-cidr`` could be defined as ``10.0.0.0/8``, so as to
include IP addresses of all pods in all network namespaces:
::
kubeadm init --token-ttl 0 --pod-network-cidr=10.0.0.0/8 --apiserver-advertise-address=10.3.1.1
If Kubernetes was initialized successfully, it prints out this message:
::
Your Kubernetes master has initialized successfully!
After successful initialization, don’t forget to set up your .kube
directory as a regular user (as instructed by ``kubeadm``):
.. code:: bash
mkdir -p $HOME/.kube
sudo cp -i /etc/kubernetes/admin.conf $HOME/.kube/config
sudo chown $(id -u):$(id -g) $HOME/.kube/config
(3/4) Installing the Contiv-VPP Pod Network
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
If you have already used the Contiv-VPP plugin before, you may need to
pull the most recent Docker images on each node:
::
bash <(curl -s https://raw.githubusercontent.com/contiv/vpp/master/k8s/pull-images.sh)
Install the Contiv-VPP network for your cluster as follows:
- If you do not use the STN feature, install Contiv-vpp as follows:
::
kubectl apply -f https://raw.githubusercontent.com/contiv/vpp/master/k8s/contiv-vpp.yaml
- If you use the STN feature, download the ``contiv-vpp.yaml`` file:
::
wget https://raw.githubusercontent.com/contiv/vpp/master/k8s/contiv-vpp.yaml
Then edit the STN configuration as described
`here <https://github.com/contiv/vpp/tree/master/docs/SINGLE_NIC_SETUP.md#configuring-stn-in-contiv-vpp-k8s-deployment-files>`__.
Finally, create the Contiv-vpp deployment from the edited file:
::
kubectl apply -f ./contiv-vpp.yaml
Beware contiv-etcd data is persisted in ``/var/etcd`` by default. It has
to be cleaned up manually after ``kubeadm reset``. Otherwise outdated
data will be loaded by a subsequent deployment.
You can also generate random subfolder, alternatively:
::
curl --silent https://raw.githubusercontent.com/contiv/vpp/master/k8s/contiv-vpp.yaml | sed "s/\/var\/etcd\/contiv-data/\/var\/etcd\/contiv-data\/$RANDOM/g" | kubectl apply -f -
Deployment Verification
^^^^^^^^^^^^^^^^^^^^^^^
After some time, all contiv containers should enter the running state:
::
root@cvpp:/home/jan# kubectl get pods -n kube-system -o wide | grep contiv
NAME READY STATUS RESTARTS AGE IP NODE
...
contiv-etcd-gwc84 1/1 Running 0 14h 192.168.56.106 cvpp
contiv-ksr-5c2vk 1/1 Running 2 14h 192.168.56.106 cvpp
contiv-vswitch-l59nv 2/2 Running 0 14h 192.168.56.106 cvpp
In particular, make sure that the Contiv-VPP pod IP addresses are the
same as the IP address specified in the
``--apiserver-advertise-address=<ip-address>`` argument to kubeadm init.
Verify that the VPP successfully grabbed the network interface specified
in the VPP startup config (``GigabitEthernet0/4/0`` in our case):
::
$ sudo vppctl
vpp# sh inter
Name Idx State Counter Count
GigabitEthernet0/4/0 1 up rx packets 1294
rx bytes 153850
tx packets 512
tx bytes 21896
drops 962
ip4 1032
host-40df9b44c3d42f4 3 up rx packets 126601
rx bytes 44628849
tx packets 132155
tx bytes 27205450
drops 24
ip4 126585
ip6 16
host-vppv2 2 up rx packets 132162
rx bytes 27205824
tx packets 126658
tx bytes 44634963
drops 15
ip4 132147
ip6 14
local0 0 down
You should also see the interface to kube-dns (``host-40df9b44c3d42f4``)
and to the node’s IP stack (``host-vppv2``).
Master Isolation (Optional)
^^^^^^^^^^^^^^^^^^^^^^^^^^^
By default, your cluster will not schedule pods on the master for
security reasons. If you want to be able to schedule pods on the master,
(e.g., for a single-machine Kubernetes cluster for development), then
run:
::
kubectl taint nodes --all node-role.kubernetes.io/master-
More details about installing the pod network can be found in the
`kubeadm
manual <https://kubernetes.io/docs/setup/independent/create-cluster-kubeadm/#pod-network>`__.
(4/4) Joining Your Nodes
~~~~~~~~~~~~~~~~~~~~~~~~
To add a new node to your cluster, run as root the command that was
output by kubeadm init. For example:
::
kubeadm join --token <token> <master-ip>:<master-port> --discovery-token-ca-cert-hash sha256:<hash>
More details can be found int the `kubeadm
manual <https://kubernetes.io/docs/setup/independent/create-cluster-kubeadm/#joining-your-nodes>`__.
.. _deployment-verification-1:
Deployment Verification
^^^^^^^^^^^^^^^^^^^^^^^
After some time, all contiv containers should enter the running state:
::
root@cvpp:/home/jan# kubectl get pods -n kube-system -o wide | grep contiv
NAME READY STATUS RESTARTS AGE IP NODE
contiv-etcd-gwc84 1/1 Running 0 14h 192.168.56.106 cvpp
contiv-ksr-5c2vk 1/1 Running 2 14h 192.168.56.106 cvpp
contiv-vswitch-h6759 2/2 Running 0 14h 192.168.56.105 cvpp-slave2
contiv-vswitch-l59nv 2/2 Running 0 14h 192.168.56.106 cvpp
etcd-cvpp 1/1 Running 0 14h 192.168.56.106 cvpp
kube-apiserver-cvpp 1/1 Running 0 14h 192.168.56.106 cvpp
kube-controller-manager-cvpp 1/1 Running 0 14h 192.168.56.106 cvpp
kube-dns-545bc4bfd4-fr6j9 3/3 Running 0 14h 10.1.134.2 cvpp
kube-proxy-q8sv2 1/1 Running 0 14h 192.168.56.106 cvpp
kube-proxy-s8kv9 1/1 Running 0 14h 192.168.56.105 cvpp-slave2
kube-scheduler-cvpp 1/1 Running 0 14h 192.168.56.106 cvpp
In particular, verify that a vswitch pod and a kube-proxy pod is running
on each joined node, as shown above.
On each joined node, verify that the VPP successfully grabbed the
network interface specified in the VPP startup config
(``GigabitEthernet0/4/0`` in our case):
::
$ sudo vppctl
vpp# sh inter
Name Idx State Counter Count
GigabitEthernet0/4/0 1 up
...
From the vpp CLI on a joined node you can also ping kube-dns to verify
node-to-node connectivity. For example:
::
vpp# ping 10.1.134.2
64 bytes from 10.1.134.2: icmp_seq=1 ttl=64 time=.1557 ms
64 bytes from 10.1.134.2: icmp_seq=2 ttl=64 time=.1339 ms
64 bytes from 10.1.134.2: icmp_seq=3 ttl=64 time=.1295 ms
64 bytes from 10.1.134.2: icmp_seq=4 ttl=64 time=.1714 ms
64 bytes from 10.1.134.2: icmp_seq=5 ttl=64 time=.1317 ms
Statistics: 5 sent, 5 received, 0% packet loss
Deploying Example Applications
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Simple Deployment
^^^^^^^^^^^^^^^^^
You can go ahead and create a simple deployment:
::
$ kubectl run nginx --image=nginx --replicas=2
Use ``kubectl describe pod`` to get the IP address of a pod, e.g.:
::
$ kubectl describe pod nginx | grep IP
You should see two ip addresses, for example:
::
IP: 10.1.1.3
IP: 10.1.1.4
You can check the pods’ connectivity in one of the following ways: \*
Connect to the VPP debug CLI and ping any pod:
::
sudo vppctl
vpp# ping 10.1.1.3
- Start busybox and ping any pod:
::
kubectl run busybox --rm -ti --image=busybox /bin/sh
If you don't see a command prompt, try pressing enter.
/ #
/ # ping 10.1.1.3
- You should be able to ping any pod from the host:
::
ping 10.1.1.3
Deploying Pods on Different Nodes
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
to enable pod deployment on the master, untaint the master first:
::
kubectl taint nodes --all node-role.kubernetes.io/master-
In order to verify inter-node pod connectivity, we need to tell
Kubernetes to deploy one pod on the master node and one POD on the
worker. For this, we can use node selectors.
In your deployment YAMLs, add the ``nodeSelector`` sections that refer
to preferred node hostnames, e.g.:
::
nodeSelector:
kubernetes.io/hostname: vm5
Example of whole JSONs:
::
apiVersion: v1
kind: Pod
metadata:
name: nginx1
spec:
nodeSelector:
kubernetes.io/hostname: vm5
containers:
- name: nginx
: nginx
::
apiVersion: v1
kind: Pod
metadata:
name: nginx2
spec:
nodeSelector:
kubernetes.io/hostname: vm6
containers:
- name: nginx
image: nginx
After deploying the JSONs, verify they were deployed on different hosts:
::
$ kubectl get pods -o wide
NAME READY STATUS RESTARTS AGE IP NODE
nginx1 1/1 Running 0 13m 10.1.36.2 vm5
nginx2 1/1 Running 0 13m 10.1.219.3 vm6
Now you can verify the connectivity to both nginx PODs from a busybox
POD:
::
kubectl run busybox --rm -it --image=busybox /bin/sh
/ # wget 10.1.36.2
Connecting to 10.1.36.2 (10.1.36.2:80)
index.html 100% |*******************************************************************************************************************************************************************| 612 0:00:00 ETA
/ # rm index.html
/ # wget 10.1.219.3
Connecting to 10.1.219.3 (10.1.219.3:80)
index.html 100% |*******************************************************************************************************************************************************************| 612 0:00:00 ETA
Uninstalling Contiv-VPP
~~~~~~~~~~~~~~~~~~~~~~~
To uninstall the network plugin itself, use ``kubectl``:
::
kubectl delete -f https://raw.githubusercontent.com/contiv/vpp/master/k8s/contiv-vpp.yaml
Tearing down Kubernetes
~~~~~~~~~~~~~~~~~~~~~~~
- First, drain the node and make sure that the node is empty before
shutting it down:
::
kubectl drain <node name> --delete-local-data --force --ignore-daemonsets
kubectl delete node <node name>
- Next, on the node being removed, reset all kubeadm installed state:
::
rm -rf $HOME/.kube
sudo su
kubeadm reset
- If you added environment variable definitions into
``/etc/systemd/system/kubelet.service.d/10-kubeadm.conf``, this would
have been a process from the `Custom Management Network
file <https://github.com/contiv/vpp/blob/master/docs/CUSTOM_MGMT_NETWORK.md#setting-up-a-custom-management-network-on-multi-homed-nodes>`__,
then remove the definitions now.
Troubleshooting
~~~~~~~~~~~~~~~
Some of the issues that can occur during the installation are:
- Forgetting to create and initialize the ``.kube`` directory in your
home directory (As instructed by ``kubeadm init --token-ttl 0``).
This can manifest itself as the following error:
::
W1017 09:25:43.403159 2233 factory_object_mapping.go:423] Failed to download OpenAPI (Get https://192.168.209.128:6443/swagger-2.0.0.pb-v1: x509: certificate signed by unknown authority (possibly because of "crypto/rsa: verification error" while trying to verify candidate authority certificate "kubernetes")), falling back to swagger
Unable to connect to the server: x509: certificate signed by unknown authority (possibly because of "crypto/rsa: verification error" while trying to verify candidate authority certificate "kubernetes")
- Previous installation lingering on the file system.
``'kubeadm init --token-ttl 0`` fails to initialize kubelet with one
or more of the following error messages:
::
...
[kubelet-check] It seems like the kubelet isn't running or healthy.
[kubelet-check] The HTTP call equal to 'curl -sSL http://localhost:10255/healthz' failed with error: Get http://localhost:10255/healthz: dial tcp [::1]:10255: getsockopt: connection refused.
...
If you run into any of the above issues, try to clean up and reinstall
as root:
::
sudo su
rm -rf $HOME/.kube
kubeadm reset
kubeadm init --token-ttl 0
rm -rf /var/etcd/contiv-data
rm -rf /var/bolt/bolt.db
Contiv-specific kubeadm installation on Aarch64
-----------------------------------------------
Supplemental instructions apply when using Contiv-VPP for Aarch64. Most
installation steps for Aarch64 are the same as that described earlier in
this chapter, so you should firstly read it before you start the
installation on Aarch64 platform.
Use the `Aarch64-specific kubeadm install
instructions <https://github.com/contiv/vpp/blob/master/docs/arm64/MANUAL_INSTALL_ARM64.md>`__
to manually install Kubernetes with Contiv-VPP networking on one or more
bare-metals of Aarch64 platform.