Rollback port no. 

Roll back the default port for policy, sdc and dcae

Issue-ID: CLAMP-153
Change-Id: I750def8dabd0d45eda1c68fb592259cf8cfb7cbd
Signed-off-by: xg353y <xg353y@intl.att.com>
diff --git a/src/main/resources/application.properties b/src/main/resources/application.properties
index d6be03c..c1c0116 100644
--- a/src/main/resources/application.properties
+++ b/src/main/resources/application.properties
@@ -125,9 +125,9 @@
 #

 #

 # Configuration Settings for Policy Engine Components

-clamp.config.policy.pdpUrl1=http://policy.api.simpledemo.onap.org:8085/pdp/ , testpdp, alpha123

-clamp.config.policy.pdpUrl2=http://policy.api.simpledemo.onap.org:8085/pdp/ , testpdp, alpha123

-clamp.config.policy.papUrl=http://policy.api.simpledemo.onap.org:8085/pap/ , testpap, alpha123

+clamp.config.policy.pdpUrl1=http://policy.api.simpledemo.onap.org:8081/pdp/ , testpdp, alpha123

+clamp.config.policy.pdpUrl2=http://policy.api.simpledemo.onap.org:8081/pdp/ , testpdp, alpha123

+clamp.config.policy.papUrl=http://policy.api.simpledemo.onap.org:8081/pap/ , testpap, alpha123

 clamp.config.policy.notificationType=websocket

 clamp.config.policy.notificationUebServers=localhost

 clamp.config.policy.notificationTopic=

@@ -181,9 +181,9 @@
 clamp.config.op.eNodeB.period=10s

 #

 # Sdc service properties

-clamp.config.sdc.catalog.url=http://sdc.api.simpledemo.onap.org:8085/sdc/v1/catalog/

-clamp.config.sdc.hostUrl=http://sdc.api.simpledemo.onap.org:8085

-clamp.config.sdc.serviceUrl=http://sdc.api.simpledemo.onap.org:8085/sdc/v1/catalog/services

+clamp.config.sdc.catalog.url=http://sdc.api.simpledemo.onap.org:8080/sdc/v1/catalog/

+clamp.config.sdc.hostUrl=http://sdc.api.simpledemo.onap.org:8080

+clamp.config.sdc.serviceUrl=http://sdc.api.simpledemo.onap.org:8080/sdc/v1/catalog/services

 clamp.config.sdc.serviceUsername=clamp

 clamp.config.sdc.servicePassword=b7acccda32b98c5bb7acccda32b98c5b05D511BD6D93626E90D18E9D24D9B78CD34C7EE8012F0A189A28763E82271E50A5D4EC10C7D93E06E0A2D27CAE66B981

 clamp.config.sdc.artifactLabel=blueprintclampcockpit

@@ -207,12 +207,12 @@
 clamp.config.clds.service.cache.invalidate.after.seconds=120

 

 #DCAE Inventory Url Properties

-clamp.config.dcae.inventory.url=http://dcae.api.simpledemo.onap.org:8085

+clamp.config.dcae.inventory.url=http://dcae.api.simpledemo.onap.org:8080

 clamp.config.dcae.intentory.retry.interval=10000

 clamp.config.dcae.intentory.retry.limit=3

 

 #DCAE Dispatcher Url Properties

-clamp.config.dcae.dispatcher.url=http://dcae.api.simpledemo.onap.org:8085

+clamp.config.dcae.dispatcher.url=http://dcae.api.simpledemo.onap.org:8080

 clamp.config.dcae.header.requestId = X-ECOMP-RequestID

 

 #Define user permission related parameters, the permission type can be changed but MUST be redefined in clds-users.properties in that case !