blob: 18e165e6520e14dae3ae006bc667e9fd3fb10809 [file] [log] [blame]
Dongho Kim287b75a2020-04-09 10:52:13 -07001.. This work is licensed under a Creative Commons Attribution 4.0
2 International License. http://creativecommons.org/licenses/by/4.0
3
4.. _docs_5g_a1_adaptor:
5
65G - A1 Adaptor
7---------------
8
9Description
10~~~~~~~~~~~
11
12A1 is an O-RAN defined interface between Non-Real Time RIC (Ran Intelligent Controller) in the management platform (ONAP) and RAN network element called Near-Real Time RIC.
13A1 interface is used to communicate policy choices, AI/ML model updates, and other RAN functions that are not included in the traditional network configuration.
14O-RAN defines architecture of RT RIC and relevant interfaces.
15O-RAN WG2 has released the first version of A1 specifications September 2019.
16ONAP needed to implement a module serving a communication channel between other ONAP components and RT RIC for A1 interface.
17ONAP community has a harmonization project with mobility standard and A1 adaptor has been proposed in the project (https://wiki.onap.org/display/DW/MOBILITY+STANDARDS+HARMONIZATION+WITH+ONAP).
18A1 adaptor has been implemented as a component in CCSDK. All implementation details are explained here: https://wiki.onap.org/display/DW/A1+Adapter+in+ONAP
19
20How to Use
21~~~~~~~~~~
22
23Following steps describe a general procedure about how to use A1 adaptor.
24
251. ONAP Frankfurt includes A1 adaptor.
26
272. Edit A1 adaptor property file in sdnc container at dev-sdnc-x POD. (dev is an example of release name and x is replica number)
28
29 a. A property file is located at /opt/onap/ccsdk/data/properties/a1-adapter-api-dg.properties.
30
31 b. SSH into a rancher node (NFS/rancher).
32
33 c. sudo su
34
35 d. kubectl get pods -n onap -o wide | grep sdnc
36
37 e. execute the following command to all sdnc PODs to update properties files.
38
39 - kubectl exec -it dev-sdnc-x bash (x=0,1,2, depending on number of sdnc replicas in the setup)
40
41 f. Once in the docker, edit the properties file.
42
43 g. Make following configuration changes per setup
44
45 - Update IP address and port number for Near-Real Time RIC as below
46
47 - near-rt-ric-id=a.b.c.d:port
48
49A1 adaptor has been tested with A1 mediator as an example of Near-Real Time RIC. Detailed information can be found at its repo: https://gerrit.o-ran-sc.org/r/gitweb?p=ric-plt%2Fric-dep.git;a=shortlog;h=refs%2Fheads%2Fmaster.
50
51Test Status and Plans
52~~~~~~~~~~~~~~~~~~~~~
53
54For ONAP Frankfurt, A1 adaptor has not been involved in a full closed loop use case. A1 adaptor has gone through a unit test with A1 mediator in OSC as a underlying device. It has been tested for receiving A1 policy via DMaaP and publishing a response back to DMaaP as well as notification. More details are presented in https://wiki.onap.org/pages/viewpage.action?pageId=71837463.