Add Test case for parameter out of schema send to VES eventBatch API
Issue-ID: INT-1455
Signed-off-by: Marcin Przybysz <marcin.przybysz@nokia.com>
Change-Id: Idb4fe6fbd2e7d61cb6f87b5bcb59db774a5edac4
diff --git a/tests/dcaegen2/testcases/assets/json_events/ves7_batch_parameter_out_of_schema.json b/tests/dcaegen2/testcases/assets/json_events/ves7_batch_parameter_out_of_schema.json
new file mode 100644
index 0000000..5245fea
--- /dev/null
+++ b/tests/dcaegen2/testcases/assets/json_events/ves7_batch_parameter_out_of_schema.json
@@ -0,0 +1,66 @@
+{
+ "eventList": [
+ {
+ "commonEventHeader": {
+ "version": "4.0.1",
+ "vesEventListenerVersion": "7.0.1",
+ "domain": "fault",
+ "dummy": "dummy_value",
+ "eventName": "Fault_Vscf:Acs-Ericcson_PilotNumberPoolExhaustion",
+ "eventId": "fault0000250",
+ "sequence": 1,
+ "priority": "High",
+ "reportingEntityId": "cc305d54-75b4-431b-adb2-eb6b9e541234",
+ "reportingEntityName": "ibcx0001vm002oam0011234",
+ "sourceId": "de305d54-75b4-431b-adb2-eb6b9e546014",
+ "sourceName": "scfx0001vm002cap001",
+ "nfVendorName": "Ericsson",
+ "nfNamingCode": "scfx",
+ "nfcNamingCode": "ssc",
+ "startEpochMicrosec": 1413378172000000,
+ "lastEpochMicrosec": 1413378172000000,
+ "timeZoneOffset": "UTC-05:30"
+ },
+ "faultFields": {
+ "faultFieldsVersion": "4.0",
+ "alarmCondition": "PilotNumberPoolExhaustion",
+ "eventSourceType": "other",
+ "specificProblem": "Calls cannot complete - pilot numbers are unavailable",
+ "eventSeverity": "CRITICAL",
+ "vfStatus": "Active",
+ "alarmAdditionalInformation": {
+ "PilotNumberPoolSize": "1000"
+ }
+ }
+ },
+ {
+ "commonEventHeader": {
+ "version": "4.0.1",
+ "vesEventListenerVersion": "7.0.1",
+ "domain": "fault",
+ "eventName": " Fault_Vscf:Acs-Ericcson_RecordingServerUnreachable",
+ "eventId": "fault0000251",
+ "sequence": 0,
+ "priority": "High",
+ "reportingEntityId": "cc305d54-75b4-431b-adb2-eb6b9e541234",
+ "reportingEntityName": "ibcx0001vm002oam0011234",
+ "sourceId": "de305d54-75b4-431b-adb2-eb6b9e546014",
+ "sourceName": "scfx0001vm002cap001",
+ "nfVendorName": "Ericsson",
+ "nfNamingCode": "scfx",
+ "nfcNamingCode": "ssc",
+ "startEpochMicrosec": 1413378172000010,
+ "lastEpochMicrosec": 1413378172000010,
+ "timeZoneOffset": "UTC-05:30"
+ },
+ "faultFields": {
+ "faultFieldsVersion": "4.0",
+ "alarmCondition": "RecordingServerUnreachable",
+ "eventSourceType": "other",
+ "specificProblem": "Recording server unreachable",
+ "eventSeverity": "CRITICAL",
+ "vfStatus": "Active"
+ }
+ }
+ ]
+}
\ No newline at end of file
diff --git a/tests/dcaegen2/testcases/dcae_ves.robot b/tests/dcaegen2/testcases/dcae_ves.robot
index 61ebf4d..60aed5f 100644
--- a/tests/dcaegen2/testcases/dcae_ves.robot
+++ b/tests/dcaegen2/testcases/dcae_ves.robot
@@ -41,7 +41,7 @@
[Documentation] Post single event with empty json to /eventListener/v7 endpoint and expect 400 Response Status Code
Send Request And Validate Response Publish Event To VES Collector ${http_session} ${VES_EVENTLISTENER_V7} ${VES_EMPTY_JSON} 400
-Publish Single VES VNF Measurement Event wit parameter out of schema
+Publish Single VES VNF Measurement Event with parameter out of schema
[Tags] DCAE-VESC-R1
[Documentation] Post single event with parameter which is not defined in schema and send to /eventListener/v7 endpoint. Expected 400 Response Status Code
Send Request And Validate Response Publish Event To VES Collector ${http_session} ${VES_EVENTLISTENER_V7} ${VES_PARAMETER_OUT_OF_SCHEMA_V7} 400
@@ -77,6 +77,11 @@
[Documentation] Post event list where one of the events doesn't have mandatory domain param, to /eventListener/v7/eventBatch endpoint and expect 400 Response Status Code
Send Request And Validate Response Publish Event To VES Collector ${http_session} ${VES_BATCH_EVENT_ENDPOINT_V7} ${VES_BATCH_MISSING_MANDATORY_PARAM_V7} 400
+Publish VES Batch Events wih parameter out of schema
+ [Tags] DCAE-VESC-R1
+ [Documentation] Post event list where one of the events have additional dummy param, to /eventListener/v7/eventBatch endpoint and expect 400 Response Status Code
+ Send Request And Validate Response Publish Event To VES Collector ${http_session} ${VES_BATCH_EVENT_ENDPOINT_V7} ${VES_BATCH_PARAM_OUT_OF_SCHEMA_V7} 400
+
Publish VES Event With Invalid Method
[Tags] DCAE-VESC-R1
[Documentation] Use invalid Put instead of Post method to expect 405 Response Status Code
diff --git a/tests/dcaegen2/testcases/resources/dcae_properties.robot b/tests/dcaegen2/testcases/resources/dcae_properties.robot
index dfb5bd8..587661c 100644
--- a/tests/dcaegen2/testcases/resources/dcae_properties.robot
+++ b/tests/dcaegen2/testcases/resources/dcae_properties.robot
@@ -36,6 +36,7 @@
${VES_EMPTY_JSON} %{WORKSPACE}/tests/dcaegen2/testcases/assets/json_events/ves_empty_json.json
${VES_VALID_BATCH_JSON_V7} %{WORKSPACE}/tests/dcaegen2/testcases/assets/json_events/ves7_batch_valid.json
${VES_BATCH_MISSING_MANDATORY_PARAM_V7} %{WORKSPACE}/tests/dcaegen2/testcases/assets/json_events/ves7_batch_missing_mandatory_parameter.json
+${VES_BATCH_PARAM_OUT_OF_SCHEMA_V7} %{WORKSPACE}/tests/dcaegen2/testcases/assets/json_events/ves7_batch_parameter_out_of_schema.json
${EVENT_DATA_FILE} %{WORKSPACE}/tests/dcaegen2/testcases/assets/json_events/ves_volte_single_fault_event.json
${EVENT_MEASURE_FILE} %{WORKSPACE}/tests/dcaegen2/testcases/assets/json_events/ves_vfirewall_measurement.json
${EVENT_DATA_FILE_BAD} %{WORKSPACE}/tests/dcaegen2/testcases/assets/json_events/ves_volte_single_fault_event_bad.json