Add test case for missing mandatory "domain" parameter in /eventListener/v7 VES API
Issue-ID: INT-1421
Signed-off-by: Marcin Przybysz <marcin.przybysz@nokia.com>
Change-Id: Ia8e3b0e5c8e5f838608f40e650109eb312430f48
diff --git a/tests/dcaegen2/testcases/assets/json_events/ves7_missing_mandatory_domain.json b/tests/dcaegen2/testcases/assets/json_events/ves7_missing_mandatory_domain.json
new file mode 100644
index 0000000..5178755
--- /dev/null
+++ b/tests/dcaegen2/testcases/assets/json_events/ves7_missing_mandatory_domain.json
@@ -0,0 +1,33 @@
+{
+ "event": {
+ "commonEventHeader": {
+ "version": "4.0.1",
+ "vesEventListenerVersion": "7.0.1",
+ "eventName": "Fault_Vscf:Acs-Ericcson_PilotNumberPoolExhaustion",
+ "eventId": "ab305d54-85b4-a31b-7db2-fb6b9e546015",
+ "sequence": 1,
+ "priority": "High",
+ "reportingEntityId": "cc305d54-75b4-431b-adb2-eb6b9e541234",
+ "reportingEntityName": "ibcx0001vm002oam001",
+ "sourceId": "de305d54-75b4-431b-adb2-eb6b9e546014",
+ "sourceName": "scfx0001vm002cap001",
+ "nfVendorName": "Ericsson",
+ "nfNamingCode": "scfx",
+ "nfcNamingCode": "ssc",
+ "startEpochMicrosec": 1413378172000000,
+ "lastEpochMicrosec": 1413378172000000,
+ "timeZoneOffset": "UTC-05:30"
+ },
+ "faultFields": {
+ "faultFieldsVersion": "4.0",
+ "alarmCondition": "PilotNumberPoolExhaustion",
+ "eventSourceType": "other",
+ "specificProblem": "Calls cannot complete - pilot numbers are unavailable",
+ "eventSeverity": "CRITICAL",
+ "vfStatus": "Active",
+ "alarmAdditionalInformation": {
+ "PilotNumberPoolSize": "1000"
+ }
+ }
+ }
+}
diff --git a/tests/dcaegen2/testcases/dcae_ves.robot b/tests/dcaegen2/testcases/dcae_ves.robot
index 48912e1..e12097e 100644
--- a/tests/dcaegen2/testcases/dcae_ves.robot
+++ b/tests/dcaegen2/testcases/dcae_ves.robot
@@ -31,6 +31,11 @@
[Documentation] Post single event with invalid data to /eventListener/v7 endpoint and expect 400 Response Status Code
Send Request And Validate Response Publish Event To VES Collector ${http_session} ${VES_EVENTLISTENER_V7} ${VES_INVALID_JSON_V7} 400
+Publish Single VES VNF Measurement Event with missing mandatory parameter domain
+ [Tags] DCAE-VESC-R1
+ [Documentation] Post single event with lack of one of the mandatory parameters "domain" to /eventListener/v7 endpoint and expect 400 Response Status Code
+ Send Request And Validate Response Publish Event To VES Collector ${http_session} ${VES_EVENTLISTENER_V7} ${VES_MISSING_MANDATORY_DOMAIN_V7} 400
+
Publish Single VES VNF Measurement Event with No Auth over HTTPS
[Tags] DCAE-VESC-R1
[Documentation] Post single event over HTTPS with authentication disabled and expect ConnectionError
diff --git a/tests/dcaegen2/testcases/resources/dcae_properties.robot b/tests/dcaegen2/testcases/resources/dcae_properties.robot
index 119ef23..5262330 100644
--- a/tests/dcaegen2/testcases/resources/dcae_properties.robot
+++ b/tests/dcaegen2/testcases/resources/dcae_properties.robot
@@ -31,6 +31,7 @@
${VES_BATCH_EVENT_ENDPOINT_V7} /eventListener/v7/eventBatch
${VES_VALID_JSON_V7} %{WORKSPACE}/tests/dcaegen2/testcases/assets/json_events/ves7_valid.json
${VES_INVALID_JSON_V7} %{WORKSPACE}/tests/dcaegen2/testcases/assets/json_events/ves7_invalid.json
+${VES_MISSING_MANDATORY_DOMAIN_V7} %{WORKSPACE}/tests/dcaegen2/testcases/assets/json_events/ves7_missing_mandatory_domain.json
${VES_VALID_BATCH_JSON_V7} %{WORKSPACE}/tests/dcaegen2/testcases/assets/json_events/ves7_batch_valid.json
${EVENT_DATA_FILE} %{WORKSPACE}/tests/dcaegen2/testcases/assets/json_events/ves_volte_single_fault_event.json
${EVENT_MEASURE_FILE} %{WORKSPACE}/tests/dcaegen2/testcases/assets/json_events/ves_vfirewall_measurement.json