| .. This work is licensed under a Creative Commons Attribution 4.0 International License. |
| .. http://creativecommons.org/licenses/by/4.0 |
| |
| .. _run_time_configuration: |
| |
| Run-Time configuration |
| ====================== |
| |
| (see :ref:`deployment`) |
| |
| HV-VES fetches configuration from Config Binding Service in the following JSON format: |
| |
| .. code-block:: json |
| |
| { |
| "dmaap.kafkaBootstrapServers": "message-router-kafka:9093", |
| "collector.routing": [ |
| { |
| "fromDomain": "perf3gpp", |
| "toTopic": "HV_VES_PERF3GPP" |
| }, |
| { |
| "fromDomain": "heartbeat", |
| "toTopic": "HV_VES_HEARTBEAT" |
| }, |
| ... |
| ] |
| } |
| |
| HV-VES does not verify the correctness of configuration data and uses them as is, in particular: |
| |
| - **KafkaBootstrapServers** is used as host name and port for publishing events to Kafka service. |
| - Every **routing** array object specifies one event publishing route. |
| |
| - **fromDomain** node should be a case-sensitive string of single domain taken from VES Common Event Header specification. |
| - **toTopic** should be a case-sensitive string of Kafka topic. |
| - When HV-VES receives VES Event, it checks the domain contained in it. If the route from that domain to any topic exists in configuration, then HV-VES publishes that event to topic in that route. |
| - If there are two routes from the same domain to different topics, then it is undefined which route will be used. |
| |
| The configuration is created from HV-VES Cloudify blueprint by specifying **application_config** node during ONAP OOM/Kubernetes deployment. Example of the node specification: |
| |
| .. code-block:: YAML |
| |
| node_templates: |
| hv-ves: |
| properties: |
| application_config: |
| dmaap.kafkaBootstrapServers: message-router-kafka:9092 |
| collector.routing: |
| fromDomain: perf3gpp |
| toTopic: HV_VES_PERF3GPP |
| |
| HV-VES waits 10 seconds (default, configurable during deployment with **firstRequestDelay** option, see :ref:`configuration_file`) before the first attempt to retrieve configuration from CBS. This is to prevent possible synchronization issues. During that time HV-VES declines any connection attempts from xNF (VNF/PNF). |
| |
| After first request, HV-VES asks for configuration in fixed intervals, configurable from file configuration (**requestInterval**). By default interval is set to 5 seconds. |
| |
| In case of failing to retrieve configuration, collector retries the action. After five unsuccessful attempts, container becomes unhealthy and cannot recover. HV-VES in this state is unusable and the container should be restarted. |