| CCVPN |
| ---------------------------- |
| |
| Sevice used for CCVPN |
| ~~~~~~~~~~~~ |
| |
| - SOTNVPNInfraService, SDWANVPNInfraService and SIteService: https://wiki.onap.org/display/DW/CCVPN+Service+Design |
| - WanConnectionService ( Another way to describe CCVPN in a single service form which based on ONF CIM ): https://wiki.onap.org/display/DW/CCVPN+Wan+Connection+Service+Design |
| |
| Description |
| ~~~~~~~~~~~ |
| Cross-domain, cross-layer VPN (CCVPN) is one of the use cases of the ONAP Casablanca release. This release demonstrates cross-operator ONAP orchestration and interoperability with third party SDN controllers and enables cross-domain, cross-layer and cross-operator service creation and assurance. |
| |
| The demonstration includes two ONAP instances, one deployed by Vodafone and one by China Mobile, both of which orchestrate the respective operator underlay OTN networks and overlay SD-WAN networks and peer to each other for cross-operator VPN service delivery. |
| |
| The CCVPN Use Case Wiki Page can be found here: https://wiki.onap.org/display/DW/CCVPN%28Cross+Domain+and+Cross+Layer+VPN%29+USE+CASE. |
| |
| The projects covered by this use case include: SDC, A&AI, UUI, SO, SDNC, OOF, Policy, DCAE(Holmes), External API, MSB |
| |
| How to Use |
| ~~~~~~~~~~ |
| Design time |
| SOTNVPNInfraService, SDWANVPNInfraService and SIteService service Design steps can be found here: https://wiki.onap.org/display/DW/CCVPN+Service+Design |
| WanConnectionService ( Another way to describe CCVPN in a single service form which based on ONF CIM ): https://wiki.onap.org/display/DW/CCVPN+Wan+Connection+Service+Design |
| |
| Run Time: |
| All opertion will be triggerd by UUI, inlcuding service creation and termination, link management and topology network display. |
| |
| |
| More details can be fonud here: https://wiki.onap.org/display/DW/CCVPN+Test+Guide |
| |
| Test Status and Plans |
| ~~~~~~~~~~~~~~~~~~~~~ |
| All test case covered by this use case: https://wiki.onap.org/display/DW/CCVPN+Integration+Test+Case |
| |
| And the test status can be found: https://wiki.onap.org/display/DW/CCVPN++-Test+Status |
| |
| Known Issues and Resolutions |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 1) AAI-1923. Link Management, UUI can't delete the link to external onap otn domain. |
| |
| For the manual steps provided by A&AI team, we should follow the steps as follow |
| the only way to delete is using the forceDeleteTool shell script in the graphadmin container. |
| First we will need to find the vertex id, you should be able to get the id by making the following GET request. |
| |
| GET /aai/v14/network/ext-aai-networks/ext-aai-network/createAndDelete/esr-system-info/test-esr-system-info-id-val-0?format=raw |
| |
| :: |
| |
| { |
| "results": [ |
| { |
| "id": "20624", |
| "node-type": "pserver", |
| "url": "/aai/v13/cloud-infrastructure/pservers/pserver/pserverid14503-as988q", |
| "properties": { |
| } |
| } |
| ] |
| } |
| |
| Same goes for the ext-aai-network: |
| |
| GET /aai/v14/network/ext-aai-networks/ext-aai-network/createAndDelete?format=raw |
| |
| Retrieve the id from the above output as that will be the vertex id that you want to remove. |
| |
| Run the following command multiple times for both the esr-system-info and ext-aai-network: |
| |
| :: |
| |
| kubectl exec -it $(kubectl get pods -lapp=aai-graphadmin -n onap --template 'range .items.metadata.name"\n"end' | head -1) -n onap gosu aaiadmin /opt/app/aai-graphadmin/scripts/forceDeleteTool.sh -action DELETE_NODE -userId YOUR_ID_ANY_VALUE -vertexId VERTEX_ID |
| |
| From the above, remove the YOUR_ID_ANY_VALUE and VERTEX_ID with your info. |
| |
| 2) SDC-1955. Site service Distribution |
| |
| To overcome the Service distribution, the SO catalog has to be populated with the model information of the services and resources. |
| a) Refering to the Csar that is generated in the SDC designed as per the detailes mentioned in the below link: https://wiki.onap.org/display/DW/CCVPN+Service+Design |
| b) Download the Csar from SDC thus generated. |
| c) copy the csar to SO sdc controller pod and bpmn pod |
| kubectl -n onap get pod|grep so |
| kubectl -n onap exec -it dev-so-so-sdc-controller-c949f5fbd-qhfbl /bin/sh |
| |
| mkdir null/ASDC |
| mkdir null/ASDC/1 |
| kubectl -n onap cp service-Sdwanvpninfraservice-csar.csar dev-so-so-bpmn-infra-58796498cf-6pzmz:null/ASDC/1/service-Sdwanvpninfraservice-csar.csar |
| kubectl -n onap cp service-Sdwanvpninfraservice-csar.csar dev-so-so-bpmn-infra-58796498cf-6pzmz:ASDC/1/service-Sdwanvpninfraservice-csar.csar |
| |
| d) populate model information to SO db |
| the db script example can be seen in https://wiki.onap.org/display/DW/Manual+steps+for+CCVPN+Integration+Testing |
| |
| The same would also be applicable for the integration of the client to create the service and get the details. |
| Currently the testing has been performed using the postman calls to the corresponding APIs. |
| |
| 3) SDC-1955 & SDC-1958. Site serivce parsing Error |
| |
| UUI: stored the csar which created based on beijing release under a fixed directory, If site serive can't parsed by SDC tosca parser, UUI will parse this default csar and get the input parameter |
| a) Make an available csar file for CCVPN use case. |
| b) Replace uuid of available files with what existing in SDC. |
| c) Put available csar files in UUI local path (/home/uui). |
| |
| 4) SO-1248. Csar needs to be manually placed into the bpmn corresponding directory |
| |
| After SDC distribution success, copy all csar files from so-sdc-controller: |
| connect to so-sdc-controller( eg: kubectl.exe exec -it -n onap dev-so-so-sdc-controller-77df99bbc9-stqdz /bin/sh ) |
| find out all csar files ( eg: find / -name '*.csar' ) |
| the csar files should be in this path: /app/null/ASDC/ ( eg: /app/null/ASDC/1/service-Sotnvpninfraservice-csar.csar ) |
| exit from the so-sdc-controller ( eg: exit ) |
| copy all csar files to local derectory ( eg: kubectl.exe cp onap/dev-so-so-sdc-controller-6dfdbff76c-64nf9:/app/null/ASDC/tmp/service-DemoService-csar.csar service-DemoService-csar.csar -c so-sdc-controller ) |
| |
| Copy csar files, which got from so-sdc-controller, to so-bpmn-infra |
| connect to so-bpmn-infra ( eg: kubectl.exe -n onap exec -it dev-so-so-bpmn-infra-54db5cd955-h7f5s -c so-bpmn-infra /bin/sh ) |
| check the /app/ASDC deretory, if doesn't exist, create it ( eg: mkdir /app/ASDC -p ) |
| exit from the so-bpmn-infra ( eg: exit ) |
| copy all csar files to so-bpmn-infra ( eg: kubectl.exe cp service-Siteservice-csar.csar onap/dev-so-so-bpmn-infra-54db5cd955-h7f5s:/app/ASDC/1/service-Siteservice-csar.csar ) |
| |
| all above manual steps can be found https://wiki.onap.org/display/DW/Manual+steps+for+CCVPN+Integration+Testing |